What is COV
The COV (Coefficient of Variation) in lithium-ion battery coating is a statistical indicator used to quantify the consistency of the coating process. It is calculated using the formula: COV = (Standard Deviation σ / Mean) × 100%. By eliminating differences in dimensions, this indicator reflects the dispersion degree of the dataset. A lower COV value indicates better coating uniformity.
How to Evaluate Coating Quality Using COV
Evaluation of Coating Surface Density Consistency
The COV directly reflects the degree of fluctuation in coating surface density. For example, a COV of 0.5% for coating surface density indicates that the standard deviation of the data is 0.5% of the mean value. Industry standards are as follows:
This indicator directly impacts cell capacity design. For instance, with a COV of 0.5%, a 3σ corresponds to a fluctuation of 1.5%, and the minimum cell capacity design needs to be set at 98.5% of the mean value.
Analysis of AB Surface Coating Uniformity
By using in-situ resistance testing methods (such as the BER2500 device), the resistance of the A-side, B-side, and total through-resistance of the electrode are measured respectively, and the COV value of each resistance is calculated. The larger the COV, the more uneven the distribution of the conductive network in the coating. For example, in a double-sided coating process, if there is a significant difference in the COV of AB surface resistance, it may be due to uneven distribution of conductive agents caused by slurry sedimentation or different drying rates, which may further lead to lithium plating or reduced cycle life of the battery.
Optimization Directions for Process Parameters
Precautions